Continuous monitoring of blood pressure by analyzing the blood flow sound of arteriovenous fistula in hemodialysis patients.

Continuous monitoring of blood pressure by analyzing the blood flow sound of arteriovenous fistula in hemodialysis patients.
Author Information (click to view)

Kamijo Y, Kanda E, Horiuchi H, Kounoue N, Ono K, Maeda K, Yanai A, Honda K, Tsujimoto R, Yanagi M, Ishibashi Y, Yoshida M,


Kamijo Y, Kanda E, Horiuchi H, Kounoue N, Ono K, Maeda K, Yanai A, Honda K, Tsujimoto R, Yanagi M, Ishibashi Y, Yoshida M, (click to view)

Kamijo Y, Kanda E, Horiuchi H, Kounoue N, Ono K, Maeda K, Yanai A, Honda K, Tsujimoto R, Yanagi M, Ishibashi Y, Yoshida M,

Advertisement
Share on FacebookTweet about this on TwitterShare on LinkedIn

Clinical and experimental nephrology 2017 11 10() doi 10.1007/s10157-017-1499-1
Abstract
BACKGROUND
Patients with end-stage renal disease undergoing hemodialysis (HD) have an elevated risk of cardiovascular disease-related morbidity and mortality. To prevent from such a life-threatening event, the continuous blood pressure (BP) monitoring system may contribute to detect BP decline in early stages and may help to do appropriate disposal. Our research team has introduced an electronic stethoscope (Asahi Kasei Co, Ltd., Tokyo, Japan), which translates sound intensity of Arteriovenous Fistula (AVF) to BP data using the technique of Fourier transformation that can predict continuous BP non-invasively. This study, we investigated whether electronic stethoscope-guided estimated BP (e-BP) would actually reflect systolic BP measured by sphygmomanometer (s-BP), and whether e-BP could predict fall of BP during HD.

METHODS
Twenty-six patients who underwent HD treatment in our hospital were evaluated prospectively. We obtained sound intensity data from the electronic stethoscope which was equipped with the return line of HD. Then, the data were translated into e-BP data to be compared with s-BP. Correlation of total of 315 data sets obtained from each method was examined. An accuracy of diagnosis of intra-dialytic hypotension (IDH) was evaluated.

RESULTS
Total of 315 data sets were obtained. A close correlation was observed between e-BP and s-BP (r = 0.887, p < 0.0001). Sensitivity and positive predictive value of predicted-BP for detection of IDH was 90 and 81.3%, respectively. CONCLUSIONS
Electronic stethoscope-guided BP measurement would be helpful for real-time diagnosis of BP fall in HD patients. Further investigations are needed.