Alteplase is the standard of care for early pharmacologic thrombolysis after acute ischemic stroke (AIS). Alteplase is also considered a high-alert medication and is fraught with potential for error. We sought to describe the difference in medication error rates in in patients receiving alteplase for acute ischemic stroke from regional hospitals compared to patients receiving alteplase at the Comprehensive Stroke Center.
This was a retrospective cohort comparison of patients who were greater than 18 years old that received intravenous alteplase for the treatment of AIS from June 2015 to June 2018. Several institution specific databases were utilized to obtain pertinent data. A standardized taxonomy was utilized to classify medication errors. Patients were excluded if they received any fibrinolytic other than alteplase or if alteplase was used for a non-stroke indication. Two cohorts (from regional hospitals or the Comprehensive Stroke Center (CSC)) were compared.
A total of 676 patients received alteplase during the study period (34% from the CSC and 66% from regional hospitals). There were 133 (19.8%) errors identified. Ten errors (1.6%) occurred at the CSC and 123 (18.2%) errors occurred at regional hospitals. More patients who had an error with alteplase administration (12.7%) experienced a hemorrhagic conversion compared to those with no error in administration (7.2%, p= 0.04).
The error rate of alteplase infusion for ischemic stroke is high, particularly in patients from referring centers. Errors may be associated with adverse events. Further education and administration safeguards should be implemented to decrease the risk of medication errors.

Copyright © 2021 Elsevier Inc. All rights reserved.

Author