Abstract
INTRODUCTION
Periprosthetic fractures are difficult to manage. Plating technique has been considered a reliable form of management of periprosthetic fractures with a well-fixed stem, but a dependable and stable method of plate fixation to the bone is lacking. This study reports the clinical results using a locking attachment plate (LAP) instead of cable fixation to fix locking plates to a periprosthetic femoral shaft fracture.

MATERIALS AND METHODS
Nineteen patients with periprosthetic femoral shaft fractures around well-fixed stemmed implants were studied between August 2012 and December 2014. Patients were followed up for at least 1 year postoperatively. Median age was 74 years (range 56-96 years). Fractures were classified according to the Unified Classification System, Vancouver classification, and Su classification.

PROCEDURE
Open reduction was performed under minimal incision and the locking plate was fixed to the lateral cortex of the femoral shaft. The part of the shaft without a stem was fixed to the plate using 5.0-mm locking screws, and the part with an underlying stem was fixed using 3.5-mm locking screws through the LAP instead of cables. Postoperatively, patients were managed using general principles for femoral shaft fractures.

RESULTS
Average follow-up was 16 months (range 12-36 months). All cases achieved fracture healing without loss of reduction. There were no cases of implant breakage or stem loosening at final follow-up. The average number of LAPs per fixation construct was 2.1 (range 1-4), and the average number of 3.5-mm locking screws through each LAP was 3.3 (range 2-4). The average value of plate screw density was 0.55 (range 0.37-0.8), and the average working length was four holes (range 2-8).

CONCLUSIONS
Using the LAP to manage periprosthetic fractures with a well-fixed stem could obviate the need for cable around the stem area and yield acceptable outcomes.