AIM
To investigate the performance of transient elastography (TE) for diagnosis of fibrosis in patients with autoimmune hepatitis-primary biliary cholangitis (AIH-PBC) overlap syndrome.

METHODS
A total of 70 patients with biopsy-proven AIH-PBC overlap syndrome were included. Spearman correlation test was used to analyze the correlation of liver stiffness measurement (LSM) and fibrosis stage. Independent samples Student’s-test or one-way analysis of variance was used to compare quantitative variables. Receiver operating characteristics (ROC) curve was used to calculate the optimal cut-off values of LSM for predicting individual fibrosis stages. A comparison on the diagnostic accuracy for severe fibrosis was made between LSM and other serological scores.

RESULTS
Patients with AIH-PBC overlap syndrome had higher median LSM than healthy controls (11.3 ± 6.4 kPa4.3 ± 1.4 kPa,< 0.01). LSM was significantly correlated with fibrosis stage (= 0.756,< 0.01). LSM values increased gradually with an increased fibrosis stage. The areas under the ROC curves of LSM for stages F ≥ 2, F ≥ 3, and F4 were 0.837 (95%CI: 0.729-0.914), 0.910 (0.817-0.965), and 0.966 (0.893-0.995), respectively. The optimal cut-off values of LSM for fibrosis stages F ≥ 2, F ≥ 3, and F4 were 6.55, 10.50, and 14.45 kPa, respectively. LSM was significantly superior to fibrosis-4, glutaglumyl-transferase/platelet ratio, and aspartate aminotransferase-to-platelet ratio index scores in detecting severe fibrosis (F ≥ 3) (0.9100.715,< 0.01; 0.9100.649,< 0.01; 0.9100.616,< 0.01, respectively). CONCLUSION
TE can accurately detect hepatic fibrosis as a non-invasive method in patients with AIH-PBC overlap syndrome.