Advertisement

 

 

Preliminary Results of Acoustic Radiation Force Impulse Imaging by Combined Qualitative and Quantitative Analyses for Evaluation of Breast Lesions.

Preliminary Results of Acoustic Radiation Force Impulse Imaging by Combined Qualitative and Quantitative Analyses for Evaluation of Breast Lesions.
Author Information (click to view)

Wang L, Wan CF, Du J, Li FH,


Wang L, Wan CF, Du J, Li FH, (click to view)

Wang L, Wan CF, Du J, Li FH,

Advertisement

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine 2018 04 15() doi 10.1002/jum.14599
Abstract
OBJECTIVES
The purpose of this study was to evaluate the application of a new elastographic technique, acoustic radiation force impulse (ARFI) imaging, and its diagnostic performance for characterizing breast lesions.

METHODS
One hundred consecutive female patients with 126 breast lesions were enrolled in our study. After routine breast ultrasound examinations, the patients underwent ARFI elasticity imaging. Virtual Touch tissue imaging (VTI) and Virtual Touch tissue quantification (Siemens Medical Solutions, Mountain View, CA) were used to qualitatively and quantitatively analyze the elasticity and hardness of tumors. A receiver operating characteristic curve analysis was performed to evaluate the diagnostic performance of ARFI for discrimination between benign and malignant breast lesions.

RESULTS
Pathologic analysis revealed 40 lesions in the malignant group and 86 lesions in the benign group. Different VTI patterns were observed in benign and malignant breast lesions. Eighty lesions (93.0%) of benign group had pattern 1, 2, or 3, whereas all pattern 4b lesions (n = 20 [50.0%]) were malignant. Regarding the quantitative analysis, the mean VTI-to-B-mode area ratio, internal shear wave velocity, and marginal shear wave velocity of benign lesions were statistically significantly lower than those of malignant lesions (all P < .001). The cutoff point for a scoring system constructed to evaluate the diagnostic performance of ARFI was estimated to be between 3 and 4 points for malignancy, with sensitivity of 77.5%, specificity of 96.5%, accuracy of 90.5%, and an area under the curve of 0.933. CONCLUSIONS
The application of ARFI technology has shown promising results by noninvasively providing substantial complementary information and could potentially serve as an effective diagnostic tool for differentiation between benign and malignant breast lesions.

Submit a Comment

Your email address will not be published. Required fields are marked *

nine − two =

[ HIDE/SHOW ]