Validation of an LC-MS/MS assay to simultaneously monitor the intracellular active metabolites of tenofovir, emtricitabine, and lamivudine in dried blood spots.

Validation of an LC-MS/MS assay to simultaneously monitor the intracellular active metabolites of tenofovir, emtricitabine, and lamivudine in dried blood spots.
Author Information (click to view)

Schauer AP, Sykes C, Cottrell ML, Prince H, Kashuba ADM,


Schauer AP, Sykes C, Cottrell ML, Prince H, Kashuba ADM, (click to view)

Schauer AP, Sykes C, Cottrell ML, Prince H, Kashuba ADM,

Advertisement
Share on FacebookTweet about this on TwitterShare on LinkedIn

Journal of pharmaceutical and biomedical analysis 2017 10 31149() 40-45 pii 10.1016/j.jpba.2017.10.030

Abstract

The ability to monitor adherence to antiretroviral therapy is critical for the interpretation of outcomes from clinical studies of HIV, and for optimizing patient care. The antiretrovirals tenofovir (TFV), emtricitabine (FTC), and lamivudine (3TC) are commonly included in drug regimens for HIV prevention and treatment. The active form of the drugs tenofovir diphosphate (TFVdp), emtricitabine triphosphate (FTCtp), and lamivudine triphosphate (3TCtp) are found intracellularly in erythrocytes and peripheral blood mononuclear cells (PBMCs). The ability to collect and analyze dried blood spot (DBS) samples is an attractive alternative to PBMC sampling in many resource limited settings. We developed and validated an assay to quantify all three intracellular metabolites over the range of 100-25000 fmol/sample. This assay utilizes a simple protein precipitation/liquid-liquid extraction of a single 3-mm DBS punch (from a Whatman 903 Protein Saver card) with isotopically labeled 13C5-TFVdp included as the internal standard. Following extraction, samples are analyzed by anion exchange chromatography on a Thermo Biobasic AX 5μm column with detection by electrospray ionization in the positive mode on a AB Sciex API-5000 triple quadrupole mass spectrometer with a total run time of 8min. The assay was linear over the entire range (R2>0.996). The assay was accurate (inter-assay%bias within ±3.0%) and precise (inter-assay % CV≤9.8%). The assay was also reproducible from multiple punches within a spot as well as punches from separate blood spots. Stability was established at room temperature for 3days, and at -80°C for up to 63days. Clinical samples were analyzed from subjects on Truvada®, Stribild®, Descovy®, and Triumeq® regimens and intracellular metabolites were detected in all samples as expected, indicating the assay performs well for all current formulations of TFV, FTC, and 3TC.

Submit a Comment

Your email address will not be published. Required fields are marked *

8 + 9 =

[ HIDE/SHOW ]