The aim of this study was to evaluate the clinical value of 16 G biopsy needle in transperineal template-guided prostate biopsy (TTPB), compared with 18 G biopsy needle.
The patients who underwent TTPB from August 2020 to February 2021 were randomized into 2 groups using a random number table. The control group (n = 65) and the observation group (n = 58) performed biopsy with 18 G (Bard MC l820) and 16 G (Bard MC l616) biopsy needles, respectively. Positive rate of biopsy, Gleason score, complications, and pain score were statistically analyzed.
The age, prostate volume, PSA, and the number of cores were comparable between the 2 groups. The positive rate of biopsy in the observation group was 68.9% (40/58), meanwhile the control group was 46.2% (30/65). There was statistical difference between the 2 groups (p = 0.011). Gleason score of the observation group (8 [7-9]) was higher than that of the control group (8 [6-9]) (p = 0.038). There was no significant difference in pain score and complications including hematuria, hematospermia, perineal hematoma, infection, and urinary retention between the 2 groups (p > 0.05).
16 G biopsy needle significantly improved the positive rates and accurately evaluate the nature of lesions, meanwhile did not increase the incidence of complications compared with 18 G biopsy needle.

© 2021 S. Karger AG, Basel.

Author