To investigate the effects of two ultrasonic vibration protocols for cast post removal (single or double ultrasound units) on the development of defects in root dentin.
Sixty bovine incisors were selected. Fifteen roots were left unprepared (control). Forty-five roots were instrumented and filled. A 10-mm post space was prepared using #1-4 Largo drills. Fifteen teeth were prepared for post space and received no further procedure. Thirty roots had cast posts cemented and were submitted to ultrasonic vibration protocols for removal. The time necessary to remove each post was recorded. Roots were sectioned 3, 6, 9, and 12 mm from the coronal portion and viewed through a 25× magnification in a stereomicroscope. The presence of root fractures, partial cracks, and craze lines was registered. Chi-square and Fisher’s exact tests were performed to compare the incidence of dentin defects. The Kruskal-Wallis test was performed to explore the difference between the time needed for post removal. The significance level was set at P = 0.05.
Root defects were observed in all experimental groups. There were no statistical differences comparing previous root canal treatment and post removal steps, either with 1 or 2 ultrasonic units, in the formation of defects (P = 0.544) or fractures (P = 0.679).
Ultrasonic vibration protocols for removing cast posts did not increase the number of dentin defects compared to root canal preparation and obturation and post space preparation steps.